Eaton DRAP124-100-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 10 uH, 3.67 A, DCR 31 mOhm.
    • Product Details
    • Download

    Eaton DRAP124-100-R Automotive Shielded Inductor 6.16 A

    DRAP124-100-R at a glance: shielded drum core inductor, 10 uH, 3.67 A Irms, 6.16 A Isat, DCR 31 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRAP124-100-R
    Rated inductance10 uH ±20%
    Open circuit inductance (OCL)10.4 uH
    Irms (40 °C rise)3.67 A
    Isat1 (30% rolloff @ +25 °C)6.16 A
    Isat2 (40% rolloff @ +125 °C)4.93 A
    DCR typical @ 20 °C31 mOhm
    DCR maximum @ 20 °C38 mOhm
    K-factor (Bp-p = K x L x dI)39.4
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    AEC-Q200 is the entry ticket, not the destination. This part is qualified to the automotive standard and rated to 165 °C ambient plus self-heating, in a shielded drum core built to survive shock and vibration rather than a laboratory bench.

    The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.

    Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    Series Positioning

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Design Notes

    10 uH sits in the middle of the range, and the trade at that point is explicit: 31 mOhm of DCR against 6.16 A of saturation headroom.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.