Eaton DRAP124-102-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 1000 uH, 0.38 A, DCR 2.94 ohm.
    • Product Details
    • Download

    Eaton DRAP124-102-R AEC-Q200 Shielded Inductor, 1000 uH

    DRAP124-102-R at a glance: shielded drum core inductor, 1000 uH, 0.38 A Irms, 0.63 A Isat, DCR 2940 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberDRAP124-102-R
    Rated inductance1000 uH ±20%
    Open circuit inductance (OCL)1001 uH
    Irms (40 °C rise)0.38 A
    Isat1 (30% rolloff @ +25 °C)0.63 A
    Isat2 (40% rolloff @ +125 °C)0.5 A
    DCR typical @ 20 °C2940 mOhm
    DCR maximum @ 20 °C3520 mOhm
    K-factor (Bp-p = K x L x dI)4
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    The Figures Explained

    This is the automotive grade version of the drum core family: AEC-Q200 qualified, shielded, and rated to 165 °C including self-temperature rise. The electrical behaviour is familiar; the qualification and the mechanical build are not.

    The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.

    Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    Positioning in the Range

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Sizing and Layout Notes

    1000 uH is at the high end of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    What does AEC-Q200 cover?
    The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.