Eaton DRAP124-150-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 15 uH, 3.1 A, DCR 44 mOhm.
    • Product Details
    • Download

    Eaton DRAP124-150-R Automotive Drum Core Inductor 15 uH

    DRAP124-150-R at a glance: shielded drum core inductor, 15 uH, 3.1 A Irms, 5.31 A Isat, DCR 44 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDRAP124-150-R
    Rated inductance15 uH ±20%
    Open circuit inductance (OCL)14.1 uH
    Irms (40 °C rise)3.1 A
    Isat1 (30% rolloff @ +25 °C)5.31 A
    Isat2 (40% rolloff @ +125 °C)4.25 A
    DCR typical @ 20 °C44 mOhm
    DCR maximum @ 20 °C53 mOhm
    K-factor (Bp-p = K x L x dI)34
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    The Figures Explained

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    At 165 °C the copper resistivity is about 60% higher than at 20 °C, so the DCR in the table is optimistic at the hot corner - budget the loss accordingly.

    Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    What This Family Is For

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Putting It to Work

    At 15 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 44 mOhm DCR - more turns, thinner wire, more resistance.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Can I use it in a non-automotive design?
    Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions