Eaton DRAP124-151-R - 150 uH AEC-Q200 Power Inductor
Eaton DRAP124-151-R - 150 uH AEC-Q200 Power Inductor

Eaton DRAP124-151-R - 150 uH AEC-Q200 Power Inductor

Share
Eaton DRAP124-151-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 150 uH, 0.97 A, DCR 454 mOhm.
    • Product Details
    • Download

    Eaton DRAP124-151-R - 150 uH AEC-Q200 Power Inductor

    DRAP124-151-R at a glance: shielded drum core inductor, 150 uH, 0.97 A Irms, 1.62 A Isat, DCR 454 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberDRAP124-151-R
    Rated inductance150 uH ±20%
    Open circuit inductance (OCL)152 uH
    Irms (40 °C rise)0.97 A
    Isat1 (30% rolloff @ +25 °C)1.62 A
    Isat2 (40% rolloff @ +125 °C)1.3 A
    DCR typical @ 20 °C454 mOhm
    DCR maximum @ 20 °C550 mOhm
    K-factor (Bp-p = K x L x dI)10.4
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    The Figures Explained

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.

    Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    What This Family Is For

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Design Notes

    150 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.