Eaton DRAP124-1R0-R Automotive Shielded Inductor 22 A
Eaton DRAP124-1R0-R Automotive Shielded Inductor 22 A

Eaton DRAP124-1R0-R Automotive Shielded Inductor 22 A

Share
Eaton DRAP124-1R0-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 1 uH, 11.7 A, DCR 3.1 mOhm.
    • Product Details
    • Download

    Eaton DRAP124-1R0-R Automotive Shielded Inductor 22 A

    DRAP124-1R0-R at a glance: shielded drum core inductor, 1 uH, 11.7 A Irms, 22 A Isat, DCR 3.1 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberDRAP124-1R0-R
    Rated inductance1 uH ±20%
    Open circuit inductance (OCL)0.82 uH
    Irms (40 °C rise)11.7 A
    Isat1 (30% rolloff @ +25 °C)22 A
    Isat2 (40% rolloff @ +125 °C)17.6 A
    DCR typical @ 20 °C3.1 mOhm
    DCR maximum @ 20 °C3.8 mOhm
    K-factor (Bp-p = K x L x dI)141
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    At 165 °C the copper resistivity is about 60% higher than at 20 °C, so the DCR in the table is optimistic at the hot corner - budget the loss accordingly.

    Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Positioning in the Range

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Putting It to Work

    1 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    Can I use it in a non-automotive design?
    Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products