Eaton DRAP124-2R2-R - 2.2 uH AEC-Q200 Power Inductor
Eaton DRAP124-2R2-R - 2.2 uH AEC-Q200 Power Inductor

Eaton DRAP124-2R2-R - 2.2 uH AEC-Q200 Power Inductor

Share
Eaton DRAP124-2R2-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 2.2 uH, 7.64 A, DCR 7 mOhm.
    • Product Details
    • Download

    Eaton DRAP124-2R2-R - 2.2 uH AEC-Q200 Power Inductor

    DRAP124-2R2-R at a glance: shielded drum core inductor, 2.2 uH, 7.64 A Irms, 14 A Isat, DCR 7 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDRAP124-2R2-R
    Rated inductance2.2 uH ±20%
    Open circuit inductance (OCL)2.04 uH
    Irms (40 °C rise)7.64 A
    Isat1 (30% rolloff @ +25 °C)14 A
    Isat2 (40% rolloff @ +125 °C)11.2 A
    DCR typical @ 20 °C7 mOhm
    DCR maximum @ 20 °C9 mOhm
    K-factor (Bp-p = K x L x dI)89.5
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    AEC-Q200 is the entry ticket, not the destination. This part is qualified to the automotive standard and rated to 165 °C ambient plus self-heating, in a shielded drum core built to survive shock and vibration rather than a laboratory bench.

    Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.

    Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    What This Family Is For

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Design Notes

    2.2 uH sits in the middle of the range, and the trade at that point is explicit: 7 mOhm of DCR against 14 A of saturation headroom.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.