Eaton DRAP124-330-R Automotive Shielded Inductor 3.42 A
Eaton DRAP124-330-R Automotive Shielded Inductor 3.42 A

Eaton DRAP124-330-R Automotive Shielded Inductor 3.42 A

Share
Eaton DRAP124-330-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 33 uH, 1.98 A, DCR 108 mOhm.
    • Product Details
    • Download

    Eaton DRAP124-330-R Automotive Shielded Inductor 3.42 A

    DRAP124-330-R at a glance: shielded drum core inductor, 33 uH, 1.98 A Irms, 3.42 A Isat, DCR 108 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDRAP124-330-R
    Rated inductance33 uH ±20%
    Open circuit inductance (OCL)34.1 uH
    Irms (40 °C rise)1.98 A
    Isat1 (30% rolloff @ +25 °C)3.42 A
    Isat2 (40% rolloff @ +125 °C)2.74 A
    DCR typical @ 20 °C108 mOhm
    DCR maximum @ 20 °C130 mOhm
    K-factor (Bp-p = K x L x dI)21.9
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.

    At 165 °C the copper resistivity is about 60% higher than at 20 °C, so the DCR in the table is optimistic at the hot corner - budget the loss accordingly.

    Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.

    Positioning in the Range

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Putting It to Work

    33 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    What does AEC-Q200 cover?
    The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.