Eaton DRAP124-331-R 330 uH AEC-Q200 Drum Core, 0.69 A
Eaton DRAP124-331-R 330 uH AEC-Q200 Drum Core, 0.69 A

Eaton DRAP124-331-R 330 uH AEC-Q200 Drum Core, 0.69 A

Share
Eaton DRAP124-331-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 330 uH, 0.69 A, DCR 892 mOhm.
    • Product Details
    • Download

    Eaton DRAP124-331-R 330 uH AEC-Q200 Drum Core, 0.69 A

    DRAP124-331-R at a glance: shielded drum core inductor, 330 uH, 0.69 A Irms, 1.09 A Isat, DCR 892 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRAP124-331-R
    Rated inductance330 uH ±20%
    Open circuit inductance (OCL)326 uH
    Irms (40 °C rise)0.69 A
    Isat1 (30% rolloff @ +25 °C)1.09 A
    Isat2 (40% rolloff @ +125 °C)0.87 A
    DCR typical @ 20 °C892 mOhm
    DCR maximum @ 20 °C1070 mOhm
    K-factor (Bp-p = K x L x dI)7
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    The Figures Explained

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    Thermal margin in a module is not the same as thermal margin on a bench. The ratings assume a mounting condition; the enclosure, the potting and the neighbouring components change it.

    Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Positioning in the Range

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Sizing It Into a Design

    At 330 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 892 mOhm DCR - more turns, thinner wire, more resistance.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    Can I use it in a non-automotive design?
    Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.