Eaton DRAP124-471-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 470 uH, 0.57 A, DCR 1.32 ohm.
    • Product Details
    • Download

    Eaton DRAP124-471-R - 470 uH AEC-Q200 Power Inductor

    DRAP124-471-R at a glance: shielded drum core inductor, 470 uH, 0.57 A Irms, 0.91 A Isat, DCR 1320 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRAP124-471-R
    Rated inductance470 uH ±20%
    Open circuit inductance (OCL)473 uH
    Irms (40 °C rise)0.57 A
    Isat1 (30% rolloff @ +25 °C)0.91 A
    Isat2 (40% rolloff @ +125 °C)0.73 A
    DCR typical @ 20 °C1320 mOhm
    DCR maximum @ 20 °C1580 mOhm
    K-factor (Bp-p = K x L x dI)5.8
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    The Figures Explained

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.

    The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.

    Series Positioning

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Putting It to Work

    At 470 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 1320 mOhm DCR - more turns, thinner wire, more resistance.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    What does AEC-Q200 cover?
    The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.