Eaton DRAP124-680-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 68 uH, 1.45 A, DCR 201 mOhm.
    • Product Details
    • Download

    Eaton DRAP124-680-R 68 uH AEC-Q200 Drum Core, 1.45 A

    DRAP124-680-R at a glance: shielded drum core inductor, 68 uH, 1.45 A Irms, 2.37 A Isat, DCR 201 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRAP124-680-R
    Rated inductance68 uH ±20%
    Open circuit inductance (OCL)69.8 uH
    Irms (40 °C rise)1.45 A
    Isat1 (30% rolloff @ +25 °C)2.37 A
    Isat2 (40% rolloff @ +125 °C)1.9 A
    DCR typical @ 20 °C201 mOhm
    DCR maximum @ 20 °C241 mOhm
    K-factor (Bp-p = K x L x dI)15.1
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    The Figures Explained

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.

    Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.

    Series Positioning

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Sizing It Into a Design

    Choose 68 uH when the ripple target is in the middle of the design window: the DCR stays at 201 mOhm and the saturation limit at 2.37 A leaves the transient room it needs.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    Can I use it in a non-automotive design?
    Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.