Eaton DRAP124-681-R AEC-Q200 Shielded Inductor, 680 uH
Eaton DRAP124-681-R AEC-Q200 Shielded Inductor, 680 uH

Eaton DRAP124-681-R AEC-Q200 Shielded Inductor, 680 uH

Share
Eaton DRAP124-681-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 680 uH, 0.47 A, DCR 1.96 ohm.
    • Product Details
    • Download

    Eaton DRAP124-681-R AEC-Q200 Shielded Inductor, 680 uH

    DRAP124-681-R at a glance: shielded drum core inductor, 680 uH, 0.47 A Irms, 0.76 A Isat, DCR 1960 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRAP124-681-R
    Rated inductance680 uH ±20%
    Open circuit inductance (OCL)682 uH
    Irms (40 °C rise)0.47 A
    Isat1 (30% rolloff @ +25 °C)0.76 A
    Isat2 (40% rolloff @ +125 °C)0.61 A
    DCR typical @ 20 °C1960 mOhm
    DCR maximum @ 20 °C2350 mOhm
    K-factor (Bp-p = K x L x dI)4.9
    Package12.5 x 12.5 x 4.6 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    The Figures Explained

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.

    Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    What This Family Is For

    DRAP124 is the four-terminal version of the 12.5 mm automotive drum core. Two extra terminals clamp the body to the board, which is what makes it survive 30 g vibration - a two-terminal part of the same size does not.

    • Typical applications: Automotive body electronics, LED lighting, ADAS, HVAC, infotainment, vibration-exposed modules.
    • The fourth terminal is mechanical, not electrical - the pad layout has to account for it, and it is not a drop-in replacement for a two-terminal DR part.
    • Data sheet 11040.

    Putting It to Work

    At 680 uH this part is at the high end of the family. The winding that produces that inductance is also what sets the 1960 mOhm DCR - more turns, thinner wire, more resistance.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Can I use it in a non-automotive design?
    Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap124-shielded-drum-core-power-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd