| Parameter | Value |
|---|---|
| Orderable part number | DRAP125-101-R |
| Rated inductance | 100 uH ±20% |
| Open circuit inductance (OCL) | 97.6 uH |
| Irms (40 °C rise) | 1.75 A |
| Isat1 (30% rolloff @ +25 °C) | 2.21 A |
| Isat2 (40% rolloff @ +125 °C) | 1.77 A |
| DCR typical @ 20 °C | 178 mOhm |
| DCR maximum @ 20 °C | 214 mOhm |
| K-factor (Bp-p = K x L x dI) | 11.8 |
| Package | 12.5 x 12.5 x 6.1 mm, four-terminal |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.
Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRAP125 takes the four-terminal construction of DRAP124 and adds height for current. Same 12.5 x 12.5 footprint, 6.1 mm body, AEC-Q200 and 30 g vibration.
100 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Why are there two Isat values?
The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd