| Parameter | Value |
|---|---|
| Orderable part number | DRAP125-471-R |
| Rated inductance | 470 uH ±20% |
| Open circuit inductance (OCL) | 466 uH |
| Irms (40 °C rise) | 0.83 A |
| Isat1 (30% rolloff @ +25 °C) | 1.01 A |
| Isat2 (40% rolloff @ +125 °C) | 0.81 A |
| DCR typical @ 20 °C | 790 mOhm |
| DCR maximum @ 20 °C | 950 mOhm |
| K-factor (Bp-p = K x L x dI) | 5.4 |
| Package | 12.5 x 12.5 x 6.1 mm, four-terminal |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.
Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.
Isat is a magnetic limit, not a thermal one. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRAP125 takes the four-terminal construction of DRAP124 and adds height for current. Same 12.5 x 12.5 footprint, 6.1 mm body, AEC-Q200 and 30 g vibration.
At 470 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 790 mOhm DCR - more turns, thinner wire, more resistance.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.