Eaton DRAP125-8R2-R - 8.2 uH AEC-Q200 Power Inductor
Eaton DRAP125-8R2-R - 8.2 uH AEC-Q200 Power Inductor

Eaton DRAP125-8R2-R - 8.2 uH AEC-Q200 Power Inductor

Share
Eaton DRAP125-8R2-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 8.2 uH, 6.41 A, DCR 13 mOhm.
    • Product Details
    • Download

    Eaton DRAP125-8R2-R - 8.2 uH AEC-Q200 Power Inductor

    DRAP125-8R2-R at a glance: shielded drum core inductor, 8.2 uH, 6.41 A Irms, 7.9 A Isat, DCR 13 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberDRAP125-8R2-R
    Rated inductance8.2 uH ±20%
    Open circuit inductance (OCL)7.49 uH
    Irms (40 °C rise)6.41 A
    Isat1 (30% rolloff @ +25 °C)7.9 A
    Isat2 (40% rolloff @ +125 °C)6.32 A
    DCR typical @ 20 °C13 mOhm
    DCR maximum @ 20 °C16 mOhm
    K-factor (Bp-p = K x L x dI)42.1
    Package12.5 x 12.5 x 6.1 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    AEC-Q200 is the entry ticket, not the destination. This part is qualified to the automotive standard and rated to 165 °C ambient plus self-heating, in a shielded drum core built to survive shock and vibration rather than a laboratory bench.

    The 165 °C figure is ambient plus self-temperature rise, which means the part can be genuinely hot in service. Derate the current for the real ambient, not for a 25 °C bench, and check the solder joint as well as the winding.

    Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Positioning in the Range

    DRAP125 takes the four-terminal construction of DRAP124 and adds height for current. Same 12.5 x 12.5 footprint, 6.1 mm body, AEC-Q200 and 30 g vibration.

    • Typical applications: Automotive DC-DC, body control, LED drivers, ADAS modules, seat and door controllers.
    • Four-terminal mounting changes the reflow profile slightly - the mechanical joints need the same solder volume as the electrical ones.
    • Data sheet 11041.

    Putting It to Work

    8.2 uH sits in the middle of the range, and the trade at that point is explicit: 13 mOhm of DCR against 7.9 A of saturation headroom.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    Can I use it in a non-automotive design?
    Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.

    Can I use it in a non-automotive design?
    Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap125-automotive-shielded-drum-core-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.