Eaton DRAP127-1R0-R 1 uH AEC-Q200 Drum Core, 13.6 A
Eaton DRAP127-1R0-R 1 uH AEC-Q200 Drum Core, 13.6 A

Eaton DRAP127-1R0-R 1 uH AEC-Q200 Drum Core, 13.6 A

Share
Eaton DRAP127-1R0-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 1 uH, 13.6 A, DCR 3.4 mOhm.
    • Product Details
    • Download

    Eaton DRAP127-1R0-R 1 uH AEC-Q200 Drum Core, 13.6 A

    DRAP127-1R0-R at a glance: shielded drum core inductor, 1 uH, 13.6 A Irms, 40 A Isat, DCR 3.4 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRAP127-1R0-R
    Rated inductance1 uH ±20%
    Open circuit inductance (OCL)0.77 uH
    Irms (40 °C rise)13.6 A
    Isat1 (30% rolloff @ +25 °C)40 A
    Isat2 (40% rolloff @ +125 °C)32 A
    DCR typical @ 20 °C3.4 mOhm
    DCR maximum @ 20 °C4 mOhm
    K-factor (Bp-p = K x L x dI)85.7
    Package12.5 x 12.5 x 8.1 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    Thermal margin in a module is not the same as thermal margin on a bench. The ratings assume a mounting condition; the enclosure, the potting and the neighbouring components change it.

    Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    What This Family Is For

    DRAP127 is the highest-current four-terminal automotive drum core at 56 A. The 8.1 mm body carries the copper; the four terminals carry the shock and vibration load.

    • Typical applications: Automotive high-current DC-DC, under-hood modules, LED lighting, ADAS power.
    • At 8.1 mm this is the tallest part in the family - plan the mechanical clearance and the potting volume before layout.
    • Data sheet 11042.

    Sizing and Layout Notes

    1 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    What is the operating temperature?
    -40 °C to +165 °C, ambient plus self-temperature rise. That covers under-hood modules with margin for the rise.

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    Can I use it in a non-automotive design?
    Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap127-automotive-shielded-drum-core-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.