| Parameter | Value |
|---|---|
| Orderable part number | DRAP127-1R5-R |
| Rated inductance | 1.5 uH ±20% |
| Open circuit inductance (OCL) | 1.27 uH |
| Irms (40 °C rise) | 12.2 A |
| Isat1 (30% rolloff @ +25 °C) | 31 A |
| Isat2 (40% rolloff @ +125 °C) | 24.9 A |
| DCR typical @ 20 °C | 4.3 mOhm |
| DCR maximum @ 20 °C | 5.1 mOhm |
| K-factor (Bp-p = K x L x dI) | 66.7 |
| Package | 12.5 x 12.5 x 8.1 mm, four-terminal |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.
Thermal margin in a module is not the same as thermal margin on a bench. The ratings assume a mounting condition; the enclosure, the potting and the neighbouring components change it.
Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DRAP127 is the highest-current four-terminal automotive drum core at 56 A. The 8.1 mm body carries the copper; the four terminals carry the shock and vibration load.
Choose 1.5 uH when the ripple target is in the middle of the design window: the DCR stays at 4.3 mOhm and the saturation limit at 31 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Can I use it in a non-automotive design?
Yes, and people do when they need the vibration and temperature headroom. You pay for the qualification you may not need.
What does AEC-Q200 cover?
The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.
Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd