Eaton DRAP127-220-R Automotive Drum Core Inductor 22 uH
Eaton DRAP127-220-R Automotive Drum Core Inductor 22 uH

Eaton DRAP127-220-R Automotive Drum Core Inductor 22 uH

Share
Eaton DRAP127-220-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 22 uH, 3.98 A, DCR 40 mOhm.
    • Product Details
    • Download

    Eaton DRAP127-220-R Automotive Drum Core Inductor 22 uH

    DRAP127-220-R at a glance: shielded drum core inductor, 22 uH, 3.98 A Irms, 7.57 A Isat, DCR 40 mOhm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberDRAP127-220-R
    Rated inductance22 uH ±20%
    Open circuit inductance (OCL)21.5 uH
    Irms (40 °C rise)3.98 A
    Isat1 (30% rolloff @ +25 °C)7.57 A
    Isat2 (40% rolloff @ +125 °C)6.05 A
    DCR typical @ 20 °C40 mOhm
    DCR maximum @ 20 °C47 mOhm
    K-factor (Bp-p = K x L x dI)16.2
    Package12.5 x 12.5 x 8.1 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.

    Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.

    Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Positioning in the Range

    DRAP127 is the highest-current four-terminal automotive drum core at 56 A. The 8.1 mm body carries the copper; the four terminals carry the shock and vibration load.

    • Typical applications: Automotive high-current DC-DC, under-hood modules, LED lighting, ADAS power.
    • At 8.1 mm this is the tallest part in the family - plan the mechanical clearance and the potting volume before layout.
    • Data sheet 11042.

    Putting It to Work

    22 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    What does AEC-Q200 cover?
    The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.

    What does AEC-Q200 cover?
    The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap127-automotive-shielded-drum-core-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd