Eaton DRAP127-471-R Automotive Shielded Inductor 1.62 A
Eaton DRAP127-471-R Automotive Shielded Inductor 1.62 A

Eaton DRAP127-471-R Automotive Shielded Inductor 1.62 A

Share
Eaton DRAP127-471-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 470 uH, 0.83 A, DCR 910 mOhm.
    • Product Details
    • Download

    Eaton DRAP127-471-R Automotive Shielded Inductor 1.62 A

    DRAP127-471-R at a glance: shielded drum core inductor, 470 uH, 0.83 A Irms, 1.62 A Isat, DCR 910 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDRAP127-471-R
    Rated inductance470 uH ±20%
    Open circuit inductance (OCL)475 uH
    Irms (40 °C rise)0.83 A
    Isat1 (30% rolloff @ +25 °C)1.62 A
    Isat2 (40% rolloff @ +125 °C)1.29 A
    DCR typical @ 20 °C910 mOhm
    DCR maximum @ 20 °C1100 mOhm
    K-factor (Bp-p = K x L x dI)3.5
    Package12.5 x 12.5 x 8.1 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    Automotive magnetics are specified differently: the temperature range is wider, the qualification is AEC-Q200, and the construction has to hold together under vibration that would shake a commercial part off its pads. That is what the DRA series is.

    Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.

    Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Series Positioning

    DRAP127 is the highest-current four-terminal automotive drum core at 56 A. The 8.1 mm body carries the copper; the four terminals carry the shock and vibration load.

    • Typical applications: Automotive high-current DC-DC, under-hood modules, LED lighting, ADAS power.
    • At 8.1 mm this is the tallest part in the family - plan the mechanical clearance and the potting volume before layout.
    • Data sheet 11042.

    Putting It to Work

    470 uH sits in the middle of the range, and the trade at that point is explicit: 910 mOhm of DCR against 1.62 A of saturation headroom.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    What does AEC-Q200 cover?
    The qualification of the component itself: thermal shock, vibration, moisture, life and electrical stress. It does not qualify your assembly or your thermal design.

    How does it differ from the commercial DR part of the same size?
    The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap127-automotive-shielded-drum-core-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message