| Parameter | Value |
|---|---|
| Orderable part number | DRAP127-680-R |
| Rated inductance | 68 uH ±20% |
| Open circuit inductance (OCL) | 68.2 uH |
| Irms (40 °C rise) | 2.33 A |
| Isat1 (30% rolloff @ +25 °C) | 4.18 A |
| Isat2 (40% rolloff @ +125 °C) | 3.34 A |
| DCR typical @ 20 °C | 115 mOhm |
| DCR maximum @ 20 °C | 138 mOhm |
| K-factor (Bp-p = K x L x dI) | 9 |
| Package | 12.5 x 12.5 x 8.1 mm, four-terminal |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +165 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant (-R suffix) |
Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.
At 165 °C the copper resistivity is about 60% higher than at 20 °C, so the DCR in the table is optimistic at the hot corner - budget the loss accordingly.
Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
DRAP127 is the highest-current four-terminal automotive drum core at 56 A. The 8.1 mm body carries the copper; the four terminals carry the shock and vibration load.
68 uH sits in the middle of the range, and the trade at that point is explicit: 115 mOhm of DCR against 4.18 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Is the part shielded?
Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
How does it differ from the commercial DR part of the same size?
The electrical shape is similar, the qualification, the temperature range and often the terminal construction are not. Do not assume drop-in equivalence.
Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.