Eaton DRAP127-8R2-R AEC-Q200 Shielded Inductor, 8.2 uH
Eaton DRAP127-8R2-R AEC-Q200 Shielded Inductor, 8.2 uH

Eaton DRAP127-8R2-R AEC-Q200 Shielded Inductor, 8.2 uH

Share
Eaton DRAP127-8R2-R: AEC-Q200 Four-Terminal Automotive Drum Core Inductor, 8.2 uH, 6.33 A, DCR 16 mOhm.
    • Product Details
    • Download

    Eaton DRAP127-8R2-R AEC-Q200 Shielded Inductor, 8.2 uH

    DRAP127-8R2-R at a glance: shielded drum core inductor, 8.2 uH, 6.33 A Irms, 12.2 A Isat, DCR 16 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberDRAP127-8R2-R
    Rated inductance8.2 uH ±20%
    Open circuit inductance (OCL)8.33 uH
    Irms (40 °C rise)6.33 A
    Isat1 (30% rolloff @ +25 °C)12.2 A
    Isat2 (40% rolloff @ +125 °C)9.74 A
    DCR typical @ 20 °C16 mOhm
    DCR maximum @ 20 °C19 mOhm
    K-factor (Bp-p = K x L x dI)26.1
    Package12.5 x 12.5 x 8.1 mm, four-terminal
    MountingSurface mount
    Operating temperature-40 °C to +165 °C
    QualificationAEC-Q200
    RoHSCompliant (-R suffix)

    The Figures Explained

    Under-hood and in-module electronics see temperature cycling, vibration and long service life. The DRA/DRAP/DRAQ parts are built for that: AEC-Q200, wider temperature range, and mechanical features that keep the part attached.

    Automotive thermal cycles are the hard part: the part may be rated to 165 °C, but every power cycle flexes the solder joint. The four-terminal variants exist precisely because two terminals are not always enough.

    Saturation degrades with temperature on ferrite. Isat1 is the 30% rolloff point at +25 °C, Isat2 the 40% rolloff at +125 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    What This Family Is For

    DRAP127 is the highest-current four-terminal automotive drum core at 56 A. The 8.1 mm body carries the copper; the four terminals carry the shock and vibration load.

    • Typical applications: Automotive high-current DC-DC, under-hood modules, LED lighting, ADAS power.
    • At 8.1 mm this is the tallest part in the family - plan the mechanical clearance and the potting volume before layout.
    • Data sheet 11042.

    Sizing and Layout Notes

    8.2 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Why are there two Isat values?
    The first is the 30% roll-off point at +25 °C, the second is the 40% roll-off at +125 °C. Hot ferrite saturates earlier, so the second number is the one to use at temperature.

    Is the part shielded?
    Yes, magnetically shielded, which is what keeps the field out of the radios, sensors and ADAS front ends that share the module.

    Design note: four terminals carry the vibration load - the mechanical joints need the same solder volume as the electrical ones, and the pad layout is not a two-terminal footprint.

    Mechanical Dimensions

    eaton-drap127-automotive-shielded-drum-core-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.