| Parameter | Value |
|---|---|
| Orderable part number | DRQ125-470-R |
| Rated inductance | 47 uH ±20% |
| Open circuit inductance (OCL) | 47.5 uH |
| Irms (40 °C rise) | 2.71 A |
| Isat | 3.24 A |
| DCR typical @ 20 °C | 74 mOhm |
| Volt-microsecond rating | 32.3 V-us |
| Series connection | 190 uH, 1.35 A |
| Parallel connection | 47 uH, 2.71 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 mm footprint, 6.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A dual-winding drum core is a single core with two identical windings. Left uncoupled it is two chokes in one package; coupled, it becomes a 1:1 transformer for a SEPIC or a flyback, or a ripple-cancelling element in a multiphase converter.
The arithmetic is the usual one for coupled windings: parallel gives L/4 with 2x the current capability, series gives 4L with half. DCR follows the same rule - parallel halves the resistance, series doubles it.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ125 is the 12.5 mm dual-winding part at 6.0 mm height. Wire the windings in parallel for a high-current single inductor, in series for a high-inductance choke, or leave them coupled as a 1:1 transformer for a SEPIC or flyback.
Choose 47 uH when the ripple target is in the middle of the design window: the DCR stays at 74 mOhm and the saturation limit at 3.24 A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd