| Parameter | Value |
|---|---|
| Orderable part number | DRQ125-471-R |
| Rated inductance | 470 uH ±20% |
| Open circuit inductance (OCL) | 473 uH |
| Irms (40 °C rise) | 0.87 A |
| Isat | 1.02 A |
| DCR typical @ 20 °C | 718 mOhm |
| Volt-microsecond rating | 102 V-us |
| Series connection | 1892 uH, 0.43 A |
| Parallel connection | 470 uH, 0.87 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 mm footprint, 6.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
One core, two windings, three possible connections. Parallel for current, series for inductance, or coupled as a transformer. The electrical ratings change by roughly a factor of four between the two extreme connections, so the connection is a design decision, not a wiring detail.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 30% rolloff at +20 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
DRQ125 is the 12.5 mm dual-winding part at 6.0 mm height. Wire the windings in parallel for a high-current single inductor, in series for a high-inductance choke, or leave them coupled as a 1:1 transformer for a SEPIC or flyback.
At 470 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 718 mOhm DCR - more turns, thinner wire, more resistance.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.