| Parameter | Value |
|---|---|
| Orderable part number | DRQ127-102-R |
| Rated inductance | 1000 uH ±20% |
| Open circuit inductance (OCL) | 1005 uH |
| Irms (40 °C rise) | 0.61 A |
| Isat | 1.14 A |
| DCR typical @ 20 °C | 1660 mOhm |
| Volt-microsecond rating | 172 V-us |
| Series connection | 4020 uH, 0.31 A |
| Parallel connection | 1000 uH, 0.61 A |
| Turns ratio | 1:1, coupled |
| Package | 12.5 x 12.5 mm footprint, 8.0 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
One core, two windings, three possible connections. Parallel for current, series for inductance, or coupled as a transformer. The electrical ratings change by roughly a factor of four between the two extreme connections, so the connection is a design decision, not a wiring detail.
The arithmetic is the usual one for coupled windings: parallel gives L/4 with 2x the current capability, series gives 4L with half. DCR follows the same rule - parallel halves the resistance, series doubles it.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ127 is the tallest dual-winding DRQ at 8.0 mm and the highest-current part in the family, up to 56 A peak in parallel mode. Two windings, one core, and the option to use it as a transformer.
1000 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.