Eaton DRQ73-101-R 100 uH Coupled Drum Core Inductor
Eaton DRQ73-101-R 100 uH Coupled Drum Core Inductor

Eaton DRQ73-101-R 100 uH Coupled Drum Core Inductor

Share
Eaton DRQ73-101-R: Dual Winding Shielded Drum Core Inductor, 100 uH, 0.73 A, DCR 527 mOhm.
    • Product Details
    • Download

    Eaton DRQ73-101-R 100 uH Coupled Drum Core Inductor

    DRQ73-101-R at a glance: dual-winding shielded drum core, 100 uH per winding, 0.73 A, DCR 527 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberDRQ73-101-R
    Rated inductance100 uH ±20%
    Open circuit inductance (OCL)101 uH
    Irms (40 °C rise)0.73 A
    Isat0.79 A
    DCR typical @ 20 °C527 mOhm
    Volt-microsecond rating36 V-us
    Series connection406 uH, 0.37 A
    Parallel connection100 uH, 0.73 A
    Turns ratio1:1, coupled
    Package7.6 x 7.6 mm footprint, 3.55 mm max height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The DRQ/DRAQ construction puts two windings on a shielded drum core with a defined 1:1 turns ratio. That ratio is what makes the part useful as a transformer: the two windings share flux, so the magnetising current is common and the ripple can be made to cancel.

    In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.

    Isat is the peak current for approximately 30% rolloff at +20 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    What This Family Is For

    DRQ73 is a dual-winding drum core: two identical windings on one core that can be wired in parallel for a low-inductance high-current choke, in series for four times the inductance, or used as a 1:1 coupled inductor or transformer. Same 7.6 mm pad as the single-winding DR73.

    • Typical applications: Buck and boost stages, SEPIC and flyback transformers, output filters, LCD panels, portable devices.
    • The two windings are isolated to 200 Vac only - this is a functional barrier for circuit reasons, not a safety isolation rating.
    • Data sheet DS4311.

    Design Notes

    At 100 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 527 mOhm DCR - more turns, thinner wire, more resistance.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What happens if I only use one winding?
    The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.

    Can I use it as a flyback transformer?
    Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.

    Does the coupling ratio matter?
    Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.

    Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

    Mechanical Dimensions

    eaton-drq-shielded-drum-core-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.