| Parameter | Value |
|---|---|
| Orderable part number | DRQ73-150-R |
| Rated inductance | 15 uH ±20% |
| Open circuit inductance (OCL) | 15 uH |
| Irms (40 °C rise) | 1.83 A |
| Isat | 2.05 A |
| DCR typical @ 20 °C | 84.4 mOhm |
| Volt-microsecond rating | 13.9 V-us |
| Series connection | 60 uH, 0.92 A |
| Parallel connection | 15 uH, 1.83 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 3.55 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A dual-winding drum core is a single core with two identical windings. Left uncoupled it is two chokes in one package; coupled, it becomes a 1:1 transformer for a SEPIC or a flyback, or a ripple-cancelling element in a multiphase converter.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DRQ73 is a dual-winding drum core: two identical windings on one core that can be wired in parallel for a low-inductance high-current choke, in series for four times the inductance, or used as a 1:1 coupled inductor or transformer. Same 7.6 mm pad as the single-winding DR73.
At 15 uH this part is in the middle of the family. The winding that produces that inductance is also what sets the 84.4 mOhm DCR - more turns, thinner wire, more resistance.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Which connection do I use?
Parallel for a high-current single inductor, series for high inductance at lower current, and coupled when you are building a SEPIC, flyback or a ripple-cancelling multiphase stage.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.