| Parameter | Value |
|---|---|
| Orderable part number | DRQ73-4R7-R |
| Rated inductance | 4.7 uH ±20% |
| Open circuit inductance (OCL) | 4.42 uH |
| Irms (40 °C rise) | 3.09 A |
| Isat | 3.78 A |
| DCR typical @ 20 °C | 29.7 mOhm |
| Volt-microsecond rating | 7.52 V-us |
| Series connection | 17.7 uH, 1.55 A |
| Parallel connection | 4.7 uH, 3.09 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 3.55 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
One core, two windings, three possible connections. Parallel for current, series for inductance, or coupled as a transformer. The electrical ratings change by roughly a factor of four between the two extreme connections, so the connection is a design decision, not a wiring detail.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DRQ73 is a dual-winding drum core: two identical windings on one core that can be wired in parallel for a low-inductance high-current choke, in series for four times the inductance, or used as a 1:1 coupled inductor or transformer. Same 7.6 mm pad as the single-winding DR73.
Choose 4.7 uH when the ripple target is in the middle of the design window: the DCR stays at 29.7 mOhm and the saturation limit at 3.78 A leaves the transient room it needs.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
How much isolation is there between windings?
The data sheet states the winding-to-winding voltage for each family. Treat it as a functional rating, not as reinforced insulation for a mains barrier.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.