| Parameter | Value |
|---|---|
| Orderable part number | DRQ73-8R2-R |
| Rated inductance | 8.2 uH ±20% |
| Open circuit inductance (OCL) | 8.93 uH |
| Irms (40 °C rise) | 2.19 A |
| Isat | 2.66 A |
| DCR typical @ 20 °C | 59.2 mOhm |
| Volt-microsecond rating | 10.7 V-us |
| Series connection | 35.7 uH, 1.1 A |
| Parallel connection | 8.2 uH, 2.19 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 3.55 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A dual-winding drum core is a single core with two identical windings. Left uncoupled it is two chokes in one package; coupled, it becomes a 1:1 transformer for a SEPIC or a flyback, or a ripple-cancelling element in a multiphase converter.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ73 is a dual-winding drum core: two identical windings on one core that can be wired in parallel for a low-inductance high-current choke, in series for four times the inductance, or used as a 1:1 coupled inductor or transformer. Same 7.6 mm pad as the single-winding DR73.
Choose 8.2 uH when the ripple target is in the middle of the design window: the DCR stays at 59.2 mOhm and the saturation limit at 2.66 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd