| Parameter | Value |
|---|---|
| Orderable part number | DRQ74-102-R |
| Rated inductance | 1000 uH ±20% |
| Open circuit inductance (OCL) | 1009 uH |
| Irms (40 °C rise) | 0.27 A |
| Isat | 0.31 A |
| DCR typical @ 20 °C | 3890 mOhm |
| Volt-microsecond rating | 100 V-us |
| Series connection | 4036 uH, 0.14 A |
| Parallel connection | 1000 uH, 0.27 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 4.35 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
A dual-winding drum core is a single core with two identical windings. Left uncoupled it is two chokes in one package; coupled, it becomes a 1:1 transformer for a SEPIC or a flyback, or a ripple-cancelling element in a multiphase converter.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ74 is the taller of the two 7.6 mm dual-winding parts at 4.35 mm, so it carries more current than DRQ73 in the same footprint. Two windings, series or parallel, 1:1 coupling when you want a transformer instead of a choke.
1000 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.