| Parameter | Value |
|---|---|
| Orderable part number | DRQ74-1R0-R |
| Rated inductance | 1 uH ±20% |
| Open circuit inductance (OCL) | 0.95 uH |
| Irms (40 °C rise) | 5.33 A |
| Isat | 10.2 A |
| DCR typical @ 20 °C | 10 mOhm |
| Volt-microsecond rating | 3.08 V-us |
| Series connection | 3.81 uH, 2.66 A |
| Parallel connection | 1 uH, 5.33 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 4.35 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Two windings on one core, and that is the whole idea: wire them in parallel and you get a high-current choke with a quarter of the inductance; wire them in series and you get four times the inductance at half the current. Same part, two very different components.
Series mode is often mistaken for a way to get more current. It is the opposite - four times the inductance, half the saturation current, twice the DCR. Use it when you need inductance, not when you need amps.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 30% rolloff at +20 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
DRQ74 is the taller of the two 7.6 mm dual-winding parts at 4.35 mm, so it carries more current than DRQ73 in the same footprint. Two windings, series or parallel, 1:1 coupling when you want a transformer instead of a choke.
Choose 1 uH when the ripple target is in the middle of the design window: the DCR stays at 10 mOhm and the saturation limit at 10.2 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
What happens if I only use one winding?
The part works as a single inductor, but the unused winding still occupies the core window - you do not get extra saturation headroom by leaving it open.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.