| Parameter | Value |
|---|---|
| Orderable part number | DRQ74-681-R |
| Rated inductance | 680 uH ±20% |
| Open circuit inductance (OCL) | 671 uH |
| Irms (40 °C rise) | 0.33 A |
| Isat | 0.38 A |
| DCR typical @ 20 °C | 2580 mOhm |
| Volt-microsecond rating | 81.7 V-us |
| Series connection | 2685 uH, 0.17 A |
| Parallel connection | 680 uH, 0.33 A |
| Turns ratio | 1:1, coupled |
| Package | 7.6 x 7.6 mm footprint, 4.35 mm max height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The DRQ/DRAQ construction puts two windings on a shielded drum core with a defined 1:1 turns ratio. That ratio is what makes the part useful as a transformer: the two windings share flux, so the magnetising current is common and the ripple can be made to cancel.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 30% rolloff at +20 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.
DRQ74 is the taller of the two 7.6 mm dual-winding parts at 4.35 mm, so it carries more current than DRQ73 in the same footprint. Two windings, series or parallel, 1:1 coupling when you want a transformer instead of a choke.
680 uH is in the middle of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
What is the OCL in parallel mode?
With the windings paralleled the effective inductance is a quarter of the single-winding OCL; the datasheet lists the parallel rating explicitly.
Can I use it as a flyback transformer?
Yes, within the isolation and the 1:1 ratio. Check the reflected voltage and the leakage inductance, because leakage is what creates the spike on the switch node.
Does the coupling ratio matter?
Yes. The turns ratio is 1:1, and the ripple cancellation depends on it. A part with a different ratio is not interchangeable in a coupled design.
Design note: decide the connection before you lay out the board. Parallel, series and coupled all use the same part, and the inductance moves by 4x between them.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd