Eaton ECST1V0703-1150-R SMT Current Transformer 150:1
Eaton ECST1V0703-1150-R SMT Current Transformer 150:1

Eaton ECST1V0703-1150-R SMT Current Transformer 150:1

Share
ECST1V0703-1150-R: current sense transformer, 2990 uH, 150:1 turns ratio, 9 A sensed.
    • Product Details
    • Download

    Eaton ECST1V0703-1150-R SMT Current Transformer 150:1

    ECST1V0703-1150-R at a glance: current sense transformer, 2990 uH, 150:1 turns ratio, 9 A sensed.

    Ratings at a Glance

    ParameterValue
    Orderable part numberECST1V0703-1150-R
    Turns ratio secondary:primary150:1
    Secondary inductance minimum2990 uH
    DCR secondary maximum22.3 Ohm
    DCR primary reference1.5 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum9 A
    Package7.2 x 5.2 x 3 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1186

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1186; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A current sense transformer measures the current in a primary conductor by stepping it down into a burden resistor. The turns ratio sets the scaling, the secondary inductance sets how low in frequency the part still works, and the secondary DCR sets how much of the signal is lost before the resistor sees it.

    With a 150:1 ratio, a 10 A primary current becomes 0.067 A in the secondary. Across a 50 ohm burden that is 3.33 V, which is what the controller actually sees.

    The secondary winding of 2990 uH with 22300 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECST1V0703 family this is item 5 of 5 in the Eaton catalogue.

    Where This Series Fits

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: switching power supplies; feedback control; overload sensing; load drop/shut down detection.
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.