Eaton ECST1V0805-1040-R Current Sense Transformer 40:1
Eaton ECST1V0805-1040-R Current Sense Transformer 40:1

Eaton ECST1V0805-1040-R Current Sense Transformer 40:1

Share
ECST1V0805-1040-R: current sense transformer, 320 uH, 40:1 turns ratio, 10 A sensed.
    • Product Details
    • Download

    Eaton ECST1V0805-1040-R Current Sense Transformer 40:1

    ECST1V0805-1040-R at a glance: current sense transformer, 320 uH, 40:1 turns ratio, 10 A sensed.

    Key Specifications

    ParameterValue
    Orderable part numberECST1V0805-1040-R
    Turns ratio secondary:primary40:1
    Secondary inductance minimum320 uH
    DCR secondary maximum1.14 Ohm
    DCR primary reference0.7 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum10 A
    Package8.38 x 8 x 5.5 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1187

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1187; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    This is a surface-mount current transformer for switching supplies: small EE core, single-turn primary, and a secondary brought out to the sense terminals. Sensed current is the primary rating; the secondary must be terminated into a burden resistor or the core will saturate.

    With a 40:1 ratio, a 10 A primary current becomes 0.25 A in the secondary. Across a 50 ohm burden that is 12.5 V, which is what the controller actually sees.

    The secondary winding of 320 uH with 1140 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECST1V0805 family this is item 3 of 8 in the Eaton catalogue.

    Series Positioning

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: switching power supplies; feedback control; overload sensing; load drop/shut down detection.
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.