Eaton ECST1V1308-1150-R Current Transformer 150:1
Eaton ECST1V1308-1150-R Current Transformer 150:1

Eaton ECST1V1308-1150-R Current Transformer 150:1

Share
ECST1V1308-1150-R: current sense transformer, 12600 uH, 150:1 turns ratio, 15 A sensed.
    • Product Details
    • Download

    Eaton ECST1V1308-1150-R Current Transformer 150:1

    ECST1V1308-1150-R at a glance: current sense transformer, 12600 uH, 150:1 turns ratio, 15 A sensed.

    Specification Table

    ParameterValue
    Orderable part numberECST1V1308-1150-R
    Turns ratio secondary:primary150:1
    Secondary inductance minimum12600 uH
    DCR secondary maximum6.5 Ohm
    DCR primary reference3.9 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum15 A
    Package13 x 11 x 7.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1188

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1188; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    This is a surface-mount current transformer for switching supplies: small EE core, single-turn primary, and a secondary brought out to the sense terminals. Sensed current is the primary rating; the secondary must be terminated into a burden resistor or the core will saturate.

    With a 150:1 ratio, a 10 A primary current becomes 0.067 A in the secondary. Across a 50 ohm burden that is 3.33 V, which is what the controller actually sees.

    The secondary winding of 12600 uH with 6500 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECST1V1308 family this is item 10 of 11 in the Eaton catalogue.

    Series Positioning

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: switching power supplies; feedback control; overload sensing; load drop/shut down detection.
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.