Eaton ECSTA1V0504-1020-R SMT Current Transformer 20:1
Eaton ECSTA1V0504-1020-R SMT Current Transformer 20:1

Eaton ECSTA1V0504-1020-R SMT Current Transformer 20:1

Share
ECSTA1V0504-1020-R: current sense transformer, 33 uH, 20:1 turns ratio, 7 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0504-1020-R SMT Current Transformer 20:1

    ECSTA1V0504-1020-R at a glance: current sense transformer, 33 uH, 20:1 turns ratio, 7 A sensed.

    Specification Table

    ParameterValue
    Orderable part numberECSTA1V0504-1020-R
    Turns ratio secondary:primary20:1
    Secondary inductance minimum33 uH
    DCR secondary maximum350 mOhm
    DCR primary reference3 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum7 A
    Package4.8 x 3.65 x 3.55 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1189

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1189; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    This is a surface-mount current transformer for switching supplies: small EE core, single-turn primary, and a secondary brought out to the sense terminals. Sensed current is the primary rating; the secondary must be terminated into a burden resistor or the core will saturate.

    With a 20:1 ratio, a 10 A primary current becomes 0.5 A in the secondary. Across a 50 ohm burden that is 25 V, which is what the controller actually sees.

    The secondary winding of 33 uH with 350 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0504 family this is item 1 of 9 in the Eaton catalogue.

    What This Family Is For

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd