Eaton ECSTA1V0504-1070-R Current Sense Transformer, 7 A
Eaton ECSTA1V0504-1070-R Current Sense Transformer, 7 A

Eaton ECSTA1V0504-1070-R Current Sense Transformer, 7 A

Share
ECSTA1V0504-1070-R: current sense transformer, 400 uH, 70:1 turns ratio, 7 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V0504-1070-R Current Sense Transformer, 7 A

    ECSTA1V0504-1070-R at a glance: current sense transformer, 400 uH, 70:1 turns ratio, 7 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECSTA1V0504-1070-R
    Turns ratio secondary:primary70:1
    Secondary inductance minimum400 uH
    DCR secondary maximum4.6 Ohm
    DCR primary reference3 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum7 A
    Package4.8 x 3.65 x 3.55 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1189

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1189; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    This is a surface-mount current transformer for switching supplies: small EE core, single-turn primary, and a secondary brought out to the sense terminals. Sensed current is the primary rating; the secondary must be terminated into a burden resistor or the core will saturate.

    With a 70:1 ratio, a 10 A primary current becomes 0.143 A in the secondary. Across a 50 ohm burden that is 7.14 V, which is what the controller actually sees.

    The secondary winding of 400 uH with 4600 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V0504 family this is item 6 of 9 in the Eaton catalogue.

    What This Family Is For

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    What defines the low-frequency limit?
    The secondary inductance and the burden resistance form a high-pass corner. Below it the output droops, which is why the inductance is quoted at a stated test frequency.