Eaton ECSTA1V1308-1040-R SMT Current Transformer 40:1
Eaton ECSTA1V1308-1040-R SMT Current Transformer 40:1

Eaton ECSTA1V1308-1040-R SMT Current Transformer 40:1

Share
ECSTA1V1308-1040-R: current sense transformer, 880 uH, 40:1 turns ratio, 15 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V1308-1040-R SMT Current Transformer 40:1

    ECSTA1V1308-1040-R at a glance: current sense transformer, 880 uH, 40:1 turns ratio, 15 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECSTA1V1308-1040-R
    Turns ratio secondary:primary40:1
    Secondary inductance minimum880 uH
    DCR secondary maximum500 mOhm
    DCR primary reference3.9 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum15 A
    Package13 x 11 x 7.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1192

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1192; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A current sense transformer measures the current in a primary conductor by stepping it down into a burden resistor. The turns ratio sets the scaling, the secondary inductance sets how low in frequency the part still works, and the secondary DCR sets how much of the signal is lost before the resistor sees it.

    With a 40:1 ratio, a 10 A primary current becomes 0.25 A in the secondary. Across a 50 ohm burden that is 12.5 V, which is what the controller actually sees.

    The secondary winding of 880 uH with 500 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V1308 family this is item 3 of 11 in the Eaton catalogue.

    Series Positioning

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.