Eaton ECSTA1V1308-1070-R Current Sense Transformer 70:1
Eaton ECSTA1V1308-1070-R Current Sense Transformer 70:1

Eaton ECSTA1V1308-1070-R Current Sense Transformer 70:1

Share
ECSTA1V1308-1070-R: current sense transformer, 2700 uH, 70:1 turns ratio, 15 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V1308-1070-R Current Sense Transformer 70:1

    ECSTA1V1308-1070-R at a glance: current sense transformer, 2700 uH, 70:1 turns ratio, 15 A sensed.

    Electrical Specifications

    ParameterValue
    Orderable part numberECSTA1V1308-1070-R
    Turns ratio secondary:primary70:1
    Secondary inductance minimum2700 uH
    DCR secondary maximum1 Ohm
    DCR primary reference3.9 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum15 A
    Package13 x 11 x 7.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1192

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1192; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    The primary is a single turn – often just a trace or a busbar through the part – and the secondary is the wound coil. That is why the primary DCR is quoted in milliohm and the secondary DCR in ohm: the two sides are built completely differently.

    With a 70:1 ratio, a 10 A primary current becomes 0.143 A in the secondary. Across a 50 ohm burden that is 7.14 V, which is what the controller actually sees.

    The secondary winding of 2700 uH with 1000 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V1308 family this is item 6 of 11 in the Eaton catalogue.

    What This Family Is For

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    What turns ratio do I need?
    Pick the ratio so the secondary current into the burden resistor gives the voltage the controller expects at the current you want to measure. Higher ratios give more resolution but more secondary inductance and DCR.

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message