Eaton ECSTA1V1308-1080-R SMT Current Transformer 80:1
Eaton ECSTA1V1308-1080-R SMT Current Transformer 80:1

Eaton ECSTA1V1308-1080-R SMT Current Transformer 80:1

Share
ECSTA1V1308-1080-R: current sense transformer, 3500 uH, 80:1 turns ratio, 15 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V1308-1080-R SMT Current Transformer 80:1

    ECSTA1V1308-1080-R at a glance: current sense transformer, 3500 uH, 80:1 turns ratio, 15 A sensed.

    Ratings at a Glance

    ParameterValue
    Orderable part numberECSTA1V1308-1080-R
    Turns ratio secondary:primary80:1
    Secondary inductance minimum3500 uH
    DCR secondary maximum1.3 Ohm
    DCR primary reference3.9 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum15 A
    Package13 x 11 x 7.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1192

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1192; the package line above gives the body size where
    the data sheet states it.

    Reading the Data Sheet

    Current sense transformers are chosen on ratio and on the volt-second capability of the secondary, because the output is a current into a burden, not a voltage source. The isolation rating between primary and secondary is what makes the part safe to use on the line side.

    With a 80:1 ratio, a 10 A primary current becomes 0.125 A in the secondary. Across a 50 ohm burden that is 6.25 V, which is what the controller actually sees.

    The secondary winding of 3500 uH with 1300 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V1308 family this is item 7 of 11 in the Eaton catalogue.

    What This Family Is For

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    How much current can the primary take?
    The sensed current column is the primary rating. It is limited by the copper and by the volt-second capability of the core, not by the winding insulation alone.

    Why must the secondary be terminated?
    The part is a current source. Left open, the secondary voltage rises until the core saturates or the insulation breaks down; the burden resistor is part of the circuit, not an optional extra.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message