Eaton ECSTA1V1308-1200-R SMT Current Transformer 200:1
Eaton ECSTA1V1308-1200-R SMT Current Transformer 200:1

Eaton ECSTA1V1308-1200-R SMT Current Transformer 200:1

Share
ECSTA1V1308-1200-R: current sense transformer, 22000 uH, 200:1 turns ratio, 15 A sensed.
    • Product Details
    • Download

    Eaton ECSTA1V1308-1200-R SMT Current Transformer 200:1

    ECSTA1V1308-1200-R at a glance: current sense transformer, 22000 uH, 200:1 turns ratio, 15 A sensed.

    Specification Table

    ParameterValue
    Orderable part numberECSTA1V1308-1200-R
    Turns ratio secondary:primary200:1
    Secondary inductance minimum22000 uH
    DCR secondary maximum8 Ohm
    DCR primary reference3.9 mOhm
    Hi-pot primary to secondary500 Vac
    Sensed current maximum15 A
    Package13 x 11 x 7.8 mm
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1192

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1192; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    Current sense transformers are chosen on ratio and on the volt-second capability of the secondary, because the output is a current into a burden, not a voltage source. The isolation rating between primary and secondary is what makes the part safe to use on the line side.

    With a 200:1 ratio, a 10 A primary current becomes 0.05 A in the secondary. Across a 50 ohm burden that is 2.5 V, which is what the controller actually sees.

    The secondary winding of 22000 uH with 8000 mOhm of resistance sets both the low-frequency corner and the signal loss; both move if you change the burden resistor.

    Within the ECSTA1V1308 family this is item 11 of 11 in the Eaton catalogue.

    What This Family Is For

    The ECST and ECSTA ranges cover 7 A to 15 A of primary current in EE4.4 to EE8.3 packages, with turns ratios from 20:1 to 200:1.

    • Never operate with the secondary open. Terminate into the burden resistor before applying primary current.
    • Typical applications: motor drive; on-board chargers; dc/dc converters; wireless chargers; battery management systems (bms).
    • Design note: the burden resistor and the secondary inductance set the bandwidth. Size the resistor first.

    Frequently Asked Questions

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Is the part AEC-Q200 qualified?
    The ECSTA versions are; the ECST versions are the commercial equivalents with the same electrical ratings.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message