
| Parameter | Value |
|---|---|
| Orderable part number | EPM12V2-05R5-12R0N |
| Input voltage range | 3-14.4 Vdc |
| Output voltage | 0.6-5.5 Vdc |
| Output current at full load | 12 A |
| Efficiency, minimum | 91 % |
| Input current, no load | 30 mA |
| Capacitive load, maximum | 200 uF |
| Package | See dimension drawing |
| Operating temperature | -40 °C to +90 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data 11183 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data 11183.
Non-isolated modules like this sit next to the load and convert a 12 V intermediate bus to the 1 V or 3.3 V the silicon needs. The input range 3-14 V covers both a 5 V and a 12 V bus.
The EPM12 series covers 12 A and 1 A versions with a programmable 0.6-5.5 V output from a 3-14 V input.
What limits the transient response?
The output capacitance and the loop bandwidth. The module is compensated internally, so the capacitor is the design variable.
What limits the transient response?
The output capacitance and the loop bandwidth. The module is compensated internally, so the capacitor is the design variable.
What is the input range good for?
3-14 V covers a 5 V rail, a 12 V rail and a 12 V battery with sag. The converter holds the output across that range without a mode change.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd