| Parameter | Value |
|---|---|
| Orderable part number | EPM12V2-05R5-12R0P |
| Input voltage range | 3-14.4 Vdc |
| Output voltage | 0.6-5.5 Vdc |
| Output current at full load | 12 A |
| Efficiency, minimum | 91 % |
| Input current, no load | 30 mA |
| Capacitive load, maximum | 200 uF |
| Package | See dimension drawing |
| Operating temperature | -40 °C to +90 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data 11183 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data 11183.
The part is a synchronous buck in a module: inductor, switches and controller in one package, with the output voltage set by an external divider. No compensation network is needed, which removes the usual loop-design step.
The EPM12 series covers 12 A and 1 A versions with a programmable 0.6-5.5 V output from a 3-14 V input.
Why non-isolated?
Because the load shares a ground with the input. Isolation would add a transformer and cost efficiency; a point-of-load converter does not need it.
Why non-isolated?
Because the load shares a ground with the input. Isolation would add a transformer and cost efficiency; a point-of-load converter does not need it.
How do I set the output voltage?
With an external resistor divider on the feedback pin. The data sheet gives the equation and the recommended values for common rails.