Eaton EPM25361V-05R-6R0S 30 W Isolated DC-DC Converter
Eaton EPM25361V-05R-6R0S 30 W Isolated DC-DC Converter

Eaton EPM25361V-05R-6R0S 30 W Isolated DC-DC Converter

Share
EPM25361V-05R-6R0S: Isolated DC-DC Converter, 9-36 V input, 5 V output, 6000 mA, 30 W, 89.00 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM25361V-05R-6R0S 30 W Isolated DC-DC Converter

    EPM25361V-05R-6R0S at a glance: Isolated DC-DC Converter, 9-36 V input, 5 V output, 6000 mA, 30 W, 89.00 % typical efficiency.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEPM25361V-05R-6R0S
    Input voltage range9-36 Vdc (nominal 24 V)
    Output voltage5 Vdc
    Output current at full load6000 mA
    Output power30 W
    Efficiency, minimum88.00 %
    Efficiency, typical89.00 %
    Capacitive load, maximum7200 uF
    Isolation voltage1.6 kVdc
    PackageSee dimension drawing
    Operating temperature-40 °C to +105 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1166

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1166.

    Reading the Data Sheet

    The module takes a wide input (4:1 range) and holds the output across it, which is what a 24 V or 48 V industrial bus needs when the battery sags. Isolation is 1.6 kVdc, and the case is the heatsink.

    At 30 W out and 89.00 % typical efficiency the module dissipates about 3.71 W. That is the number the thermal design has to carry, not the output power.

    Positioning in the Range

    The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.

    • At 60 W the case dissipates several watts. Plan the thermal path before choosing the enclosure.

    Frequently Asked Questions

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    Can I trim the output?
    The output is adjustable by about ±10 percent through the trim pin. That is enough to compensate cable drop, not enough to change the rail voltage.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products