EPM25361V-12R-1R2S: Isolated DC-DC Converter, 9-36 V input, 12 V output, 1250 mA, 15 W, 88.50 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM25361V-12R-1R2S 12V 15W DC-DC Module

    EPM25361V-12R-1R2S at a glance: Isolated DC-DC Converter, 9-36 V input, 12 V output, 1250 mA, 15 W, 88.50 % typical efficiency.

    Specification Table

    ParameterValue
    Orderable part numberEPM25361V-12R-1R2S
    Input voltage range9-36 Vdc (nominal 24 V)
    Output voltage12 Vdc
    Output current at full load1250 mA
    Output power15 W
    Efficiency, minimum87.50 %
    Efficiency, typical88.50 %
    Capacitive load, maximum1200 uF
    Isolation voltage1.6 kVdc
    PackageSee dimension drawing
    Operating temperature-40 °C to +105 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1165

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1165.

    What the Numbers Mean

    A quarter-brick style isolated converter: 9-36 V or 18-75 V input, single or dual output from 3.3 V to 24 V, 15 to 60 W. The 2 x 1 inch package and the wide input range are what make it a drop-in for industrial and telecom rails.

    At 15 W out and 88.50 % typical efficiency the module dissipates about 1.95 W. That is the number the thermal design has to carry, not the output power.

    Positioning in the Range

    The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.

    • At 60 W the case dissipates several watts. Plan the thermal path before choosing the enclosure.

    Frequently Asked Questions

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    Can I trim the output?
    The output is adjustable by about ±10 percent through the trim pin. That is enough to compensate cable drop, not enough to change the rail voltage.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.