| Parameter | Value |
|---|---|
| Orderable part number | EPM25361V-12R-R62D |
| Input voltage range | 9-36 Vdc (nominal 24 V) |
| Output voltage | ±12 Vdc |
| Output current at full load | ±625 mA |
| Output power | 7.5 W |
| Efficiency, minimum | 86.00 % |
| Efficiency, typical | 87.00 % |
| Capacitive load, maximum | 520 uF |
| Isolation voltage | 1.6 kVdc |
| Package | See dimension drawing |
| Operating temperature | -40 °C to +105 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1165 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1165.
A quarter-brick style isolated converter: 9-36 V or 18-75 V input, single or dual output from 3.3 V to 24 V, 15 to 60 W. The 2 x 1 inch package and the wide input range are what make it a drop-in for industrial and telecom rails.
At 7.5 W out and 87.00 % typical efficiency the module dissipates about 1.12 W. That is the number the thermal design has to carry, not the output power.
The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.
Does it need a minimum load?
No. The converter is specified with zero minimum load, so it holds regulation with the output open. That is not true of every module in this class.
What does the wide input range buy me?
A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.
How is the case cooled?
Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.
Shenzhen Gaorunxin Technology Co., Ltd