Eaton EPM25361V-3R3-4R0S 13.2 W DC-DC, 3.3V Output
Eaton EPM25361V-3R3-4R0S 13.2 W DC-DC, 3.3V Output

Eaton EPM25361V-3R3-4R0S 13.2 W DC-DC, 3.3V Output

Share
EPM25361V-3R3-4R0S: Isolated DC-DC Converter, 9-36 V input, 3.3 V output, 4000 mA, 13.2 W, 85.00 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM25361V-3R3-4R0S 13.2 W DC-DC, 3.3V Output

    EPM25361V-3R3-4R0S at a glance: Isolated DC-DC Converter, 9-36 V input, 3.3 V output, 4000 mA, 13.2 W, 85.00 % typical efficiency.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEPM25361V-3R3-4R0S
    Input voltage range9-36 Vdc (nominal 24 V)
    Output voltage3.3 Vdc
    Output current at full load4000 mA
    Output power13.2 W
    Efficiency, minimum84.00 %
    Efficiency, typical85.00 %
    Capacitive load, maximum12000 uF
    Isolation voltage1.6 kVdc
    PackageSee dimension drawing
    Operating temperature-40 °C to +105 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1165

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1165.

    Reading the Data Sheet

    Efficiency runs from 84 to 92 percent depending on the output voltage: the low rails lose more in the rectifiers, the high rails lose more in the turns ratio. The data sheet gives both minimum and typical so the loss budget can be built on either.

    At 13.2 W out and 85.00 % typical efficiency the module dissipates about 2.33 W. That is the number the thermal design has to carry, not the output power.

    Where This Series Fits

    The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.

    • At 60 W the case dissipates several watts. Plan the thermal path before choosing the enclosure.

    Frequently Asked Questions

    Can I trim the output?
    The output is adjustable by about ±10 percent through the trim pin. That is enough to compensate cable drop, not enough to change the rail voltage.

    Does it need a minimum load?
    No. The converter is specified with zero minimum load, so it holds regulation with the output open. That is not true of every module in this class.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    Shenzhen Gaorunxin Technology Co., Ltd