Eaton EPM25362V-12R-2R5D 9-36V Input Isolated Converter
Eaton EPM25362V-12R-2R5D 9-36V Input Isolated Converter

Eaton EPM25362V-12R-2R5D 9-36V Input Isolated Converter

Share
EPM25362V-12R-2R5D: Isolated DC-DC Converter, 9-36 V input, ±12 V output, ±2500 mA, 30 W, 91 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM25362V-12R-2R5D 9-36V Input Isolated Converter

    EPM25362V-12R-2R5D at a glance: Isolated DC-DC Converter, 9-36 V input, ±12 V output, ±2500 mA, 30 W, 91 % typical efficiency.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEPM25362V-12R-2R5D
    Input voltage range9-36 Vdc (nominal 24 V)
    Output voltage±12 Vdc
    Output current at full load±2500 mA
    Output power30 W
    Efficiency, minimum90 %
    Efficiency, typical91 %
    Capacitive load, maximum3900 uF
    Isolation voltage1.6 kVdc
    PackageSee dimension drawing
    Operating temperature-40 °C to +105 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1168

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1168.

    The Figures Explained

    The module takes a wide input (4:1 range) and holds the output across it, which is what a 24 V or 48 V industrial bus needs when the battery sags. Isolation is 1.6 kVdc, and the case is the heatsink.

    At 30 W out and 91 % typical efficiency the module dissipates about 2.97 W. That is the number the thermal design has to carry, not the output power.

    Series Positioning

    The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.

    • At 60 W the case dissipates several watts. Plan the thermal path before choosing the enclosure.

    Frequently Asked Questions

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    How is the case cooled?
    Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.

    What does the wide input range buy me?
    A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products