| Parameter | Value |
|---|---|
| Orderable part number | EPM25362V-12R-5R0S |
| Input voltage range | 9-36 Vdc (nominal 24 V) |
| Output voltage | 12 Vdc |
| Output current at full load | 5000 mA |
| Output power | 60 W |
| Efficiency, minimum | 90 % |
| Efficiency, typical | 91 % |
| Capacitive load, maximum | 5850 uF |
| Isolation voltage | 1.6 kVdc |
| Package | See dimension drawing |
| Operating temperature | -40 °C to +105 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1168 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1168.
Efficiency runs from 84 to 92 percent depending on the output voltage: the low rails lose more in the rectifiers, the high rails lose more in the turns ratio. The data sheet gives both minimum and typical so the loss budget can be built on either.
At 60 W out and 91 % typical efficiency the module dissipates about 5.93 W. That is the number the thermal design has to carry, not the output power.
The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.
What does the wide input range buy me?
A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.
How is the case cooled?
Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.
How is the case cooled?
Through the baseplate into the board or a heatsink. At 60 W the efficiency loss is several watts, so the thermal path is part of the design, not an afterthought.
Shenzhen Gaorunxin Technology Co., Ltd