| Parameter | Value |
|---|---|
| Orderable part number | EPM25751V-12R-1R2D |
| Input voltage range | 18-75 Vdc (nominal 48 V) |
| Output voltage | ±12 Vdc |
| Output current at full load | ±1250 mA |
| Output power | 15 W |
| Efficiency, minimum | 89.50 % |
| Efficiency, typical | 90.50 % |
| Capacitive load, maximum | 750 uF |
| Isolation voltage | 1.6 kVdc |
| Package | See dimension drawing |
| Operating temperature | -40 °C to +105 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1166 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1166.
This is a regulated isolated converter with a fixed switching frequency around 250 kHz, remote on/off, and no minimum load requirement. The no-minimum-load point matters: many converters of this class need a bleeder resistor to stay in regulation, and this one does not.
At 15 W out and 90.50 % typical efficiency the module dissipates about 1.57 W. That is the number the thermal design has to carry, not the output power.
The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.
What does the wide input range buy me?
A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.
Does it need a minimum load?
No. The converter is specified with zero minimum load, so it holds regulation with the output open. That is not true of every module in this class.
Can I trim the output?
The output is adjustable by about ±10 percent through the trim pin. That is enough to compensate cable drop, not enough to change the rail voltage.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd