| Parameter | Value |
|---|---|
| Orderable part number | EPM25752V-15R-2R0D |
| Input voltage range | 18-75 Vdc (nominal 48 V) |
| Output voltage | ±15 Vdc |
| Output current at full load | ±2000 mA |
| Output power | 30 W |
| Efficiency, minimum | 89 % |
| Efficiency, typical | 90 % |
| Capacitive load, maximum | 2400 uF |
| Isolation voltage | 1.6 kVdc |
| Package | See dimension drawing |
| Operating temperature | -40 °C to +105 °C |
| Qualification | Industrial |
| RoHS | Compliant |
| Data sheet | Eaton Technical Data ELX1168 |
Mechanical drawing, derating curve and application circuits are on the
following pages of Eaton Technical Data ELX1168.
The module takes a wide input (4:1 range) and holds the output across it, which is what a 24 V or 48 V industrial bus needs when the battery sags. Isolation is 1.6 kVdc, and the case is the heatsink.
At 30 W out and 90 % typical efficiency the module dissipates about 3.33 W. That is the number the thermal design has to carry, not the output power.
The 25 series covers 15, 30, 40 and 60 W in a 2 x 1 inch case, with 9-36 V and 18-75 V input ranges and single or dual outputs.
Does it need a minimum load?
No. The converter is specified with zero minimum load, so it holds regulation with the output open. That is not true of every module in this class.
Can I trim the output?
The output is adjustable by about ±10 percent through the trim pin. That is enough to compensate cable drop, not enough to change the rail voltage.
What does the wide input range buy me?
A 9-36 V input covers a 24 V bus with transients; 18-75 V covers a 48 V bus. The converter holds regulation across the whole range, so the battery can sag without dropping the rail.
Shenzhen Gaorunxin Technology Co., Ltd