Eaton EPM6052V-05R-200SR 5V Isolated DC-DC Converter
Eaton EPM6052V-05R-200SR 5V Isolated DC-DC Converter

Eaton EPM6052V-05R-200SR 5V Isolated DC-DC Converter

Share
EPM6052V-05R-200SR: Isolated DC-DC Converter, 5 V input, 5 V output, 200 mA, 1 W, 79 % typical efficiency.
    • Product Details
    • Download

    Eaton EPM6052V-05R-200SR 5V Isolated DC-DC Converter

    EPM6052V-05R-200SR at a glance: Isolated DC-DC Converter, 5 V input, 5 V output, 200 mA, 1 W, 79 % typical efficiency.

    Ratings at a Glance

    ParameterValue
    Orderable part numberEPM6052V-05R-200SR
    Input voltage range5 Vdc
    Output voltage5 Vdc
    Output current at full load200 mA
    Output power1 W
    Efficiency, minimum76 %
    Efficiency, typical79 %
    Capacitive load, maximum1500 uF
    Isolation voltage3 kVdc
    PackageSIP
    Operating temperature-40 °C to +100 °C
    QualificationIndustrial
    RoHSCompliant
    Data sheetEaton Technical Data ELX1163

    Mechanical drawing, derating curve and application circuits are on the
    following pages of Eaton Technical Data ELX1163.

    What the Numbers Mean

    A one-watt isolated module with two output rails: ±3.3, ±5, ±12 or ±15 V from a 5, 12 or 24 V input. The two rails are regulated against each other only loosely, so the cross-regulation figure matters when the load is asymmetric.

    At 1 W out and 79 % typical efficiency the module dissipates about 0.27 W. That is the number the thermal design has to carry, not the output power.

    Positioning in the Range

    The dual-output range mirrors the single-output parts: 5, 12 and 24 V inputs, ±3.3 V to ±15 V outputs, 1 W total.

    • Unbalanced loads move the opposite rail. Size the negative rail load before fixing the capacitor values.

    Frequently Asked Questions

    How good is the negative rail?
    Cross regulation is quoted as a percentage: the negative rail moves when only the positive rail is loaded. For a symmetric load it tracks well; for a single-sided load, budget for the cross-regulation figure.

    What is the difference between the R and H suffix?
    The isolation voltage option: R is the standard barrier, H is the higher isolation version. The electrical ratings are the same.

    Is the total power 1 W per rail or in total?
    In total. The current rating is per rail, but the sum of both rails times their voltages has to stay inside the watt rating.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd